flash
Home>Products>Lighting Sensor>Restroom Commercial Lighting Sensor for Rooms in Health Care Facilities> Restroom Commercial Lighting Sensor for Rooms in Health Care Facilities (JSC-366ES)
top
Restroom Commercial Lighting Sensor for Rooms in Health Care Facilities (JSC-366ES)
  • Product ID : JSC-366ES
  • Description :

The Restroom Commercial Lighting Sensor for Rooms in Health Care Facilities can be used as an energy saving restroom light control system when installed in combination with a one directional sensor to accurately control lights in single stall public restrooms. Its automatic light “ON” or “OFF” function eliminates the need to touch conventional light switches, which also makes it ideal for places where hygiene and cleanliness is emphasized. Different from the original restroom commercial lighting sensor, the Restroom Commercial Lighting Sensor for Rooms in Health Care Facilities has an added micro controller unit along with a unique circuit design to be used in combination with a one directional sensor that can differentiate whether or not the occupant of the restroom has made an exit. (sold separately, model number JSC-20) Through the LED Restroom Occupancy Indicator that is to be installed by the restroom door, the restroom occupancy status can be shown, and aids in reminding caretakers when patients or elderly are immobile in restroom or bathroom for a prolonged period of time can also be provided.

*** For use at single stall public restroom in Health Care Facilities

bottom
introduction

Model
JSC-366ES
Method of Detection
Passive Infrared (PIR)
Operating Voltage
DC12V
Power Consumption 8mA (standby)
Time Setting
(Restroom Light)
1.      Restroom light light-ON automatically upon object’s entrance into restroom (sensor A triggered).
2.      When object exits restroom (Sensor B triggered), restroom light light-OFF in 10 seconds 4.5 minutes (Adjustable 8 digit time setting combination).
LED Restroom Occupancy Indicator
LED Indicator On (Occupied)Object enters into restroom and remain motional.
LED Indicator Off (Vacancy)Object exits restroom.
Sensor Output for controlling LED IndicatorN. O. 2A maximum
LED Restroom Occupancy Indicator Flashing
Object remained motionless for 10 seconds 30 minutes (Adjustable 16 digit time setting combination) in restroom. (Sensor A and Sensor B do not triggered)
 
LED Restroom Occupancy Indicator Stop Flashing and Remain Lit
Sensor A or Sensor B triggered
Twilight Setting
101000 lux (Adjustable)
Angle of Coverage
360 degrees (Top View) 110 degrees (Side View)
Reach
8 meters maximum (At 2.8 meters mounting height under 25℃ ambient temperature)
Pulse Count
1 or 2 (Selectable with DIP switch)
Operating Temperature
1040
Output for Controlling Restroom Light
N.O. 10A maximum
Enclosure
IP44